Experimental high-pressure homogenizer

High Pressure Homogenizer Model PT-20

Model PT-20 High Pressure Homogenizer It delivers a maximum working pressure of 1800 bar with a stable throughput of 5–10 L/H. The discharge temperature fluctuation is controlled within 10℃, enabling precise high-pressure emulsification and dispersion while effectively preserving material bioactivity.

View specifications
High Pressure Homogenizer Model PT-20 Experimental high-pressure homogenizer

Core specifications

Specifications

Maximum Pressure
1800bar
Flow Capacity
≧20L/H
Feed Requirement
25 ml min.
Equipment Series
Experimental high-pressure homogenizer

Product Description

Laboratory high-pressure homogenizer

Lab Homogenizer PT-20 for Benchtop High-Pressure Trials

PT-20 is presented as a lab homogenizer for benchtop high-pressure trials and process development. Use the process question, material details and required result to define the quoted configuration.

The public summary states 5–10 L/H while the technical table lists >=20 L/H; confirm the quoted flow, temperature limit and final operating window.

Request a Solution

CAS PETER PT-20 high-pressure homogenizer in a hygienic dairy pilot factory
Model reference image from a CAS PETER process article.

Model facts

Lab Homogenizer PT-20 Specifications

The product page publishes model-level pressure, throughput, viscosity, power, temperature and feed or volume fields. Use the values below as the starting point for a process discussion and confirm the quoted configuration.

The technical table lists processing speed >=20 L/H, maximum pressure 1800 bar, viscosity <=9000, AC380V 5.5KW, operating temperature -5°C, and minimum processing 25ML.

Processing speed>=20 L/H
Maximum pressure in technical table1800 bar
Viscosity<=9000
PowerAC380V 5.5KW
Temperature or product limit-5°C
Feed or minimum processing fieldminimum processing 25ML

Quotation check: confirm the final pressure, throughput and configuration before purchase.

Selection route

How a Benchtop High Pressure Homogenizer Fits the Process

CAS PETER positions its homogenization equipment for nano dispersion, emulsification, cell disruption and scale-up discussions. The right configuration depends on material behavior, required result and operating window.

01 / RESULT

Lab Homogenizer Feed and Formulation

State whether the trial is for dispersion, emulsification, cell disruption or another formulation result before selecting the operating window.

Review applications

02 / SCALE

Benchtop High Pressure Homogenizer Duty

Compare the published throughput and minimum-volume fields with batch size, pass strategy and the volume available for validation.

Compare product family

03 / PROOF

Lab-Scale Process Result

Use a representative material brief and ask CAS PETER to confirm pressure, temperature, compatibility and records for the quoted setup.

Review case resources

Evidence and support

Laboratory Homogenizer Materials and Support

These are supplier-level statements from the captured CAS PETER pages. They explain what to discuss with the team; they do not replace model-specific compatibility or certification confirmation.

Laboratory Homogenizer Contact Materials

The technical content lists zirconia ceramic for the valve core and plunger, PTFE seals, duplex stainless steel 2205/2507, 316L, Stelli alloy zirconia ceramic, fluorine rubber sealing ring, imported UPE and Ra0.1 internal-wall roughness.

Laboratory Homogenizer Commissioning

CAS PETER’s Service page lists commissioning, process validation, operator training, maintenance planning and technical consultation.

View service scope

Lab Homogenizer Operating Support

The Support page lists application guidance, operating documentation, maintenance assistance and spare-parts enquiries.

View support scope

Trial definition

Plan a Lab Scale High Pressure Homogenizer Trial

A trial plan may start with the process result you need to demonstrate, then ask CAS PETER to confirm the operating window and records for the quoted configuration. This planning aid is not a performance guarantee.

Decision field What to provide What to confirm
Material Formulation, viscosity, solids or cell content and sensitivity. Contact-material compatibility and cleaning boundary.
Target result Dispersion, emulsification, cell disruption or another measurable outcome. Test method, sampling point and acceptance criteria.
Operating window Required pressure, throughput, temperature and pass strategy. Final rating, controls, voltage and installation conditions.
Scale-up Batch volume, repeatability needs and production handoff timing. Records, service scope, documents and commissioning plan.
STEP ONE

Describe the Lab Feed

Include the material system, viscosity, feed-particle or minimum-volume constraint and available sample volume.

STEP TWO

Set the Bench-Scale Outcome

Define the result that will decide whether the configuration moves forward.

STEP THREE

Confirm the Lab Operating Window

Ask for pressure, flow, temperature, pass strategy, voltage and material compatibility in the quotation.

STEP FOUR

Record the Trial Handoff

Agree which test records, operating guidance and support documents accompany the delivered setup.

Quotation checklist

Lab Homogenizer FAQ for Benchtop High-Pressure Trials

Price, MOQ, lead time, packaging, trade terms, warranty, available documents and the final operating rating are not published as universal terms for this model. Confirm them for the intended market and configuration.

  • Material or formulation and target application
  • Target result and validation method
  • Throughput, viscosity and feed or volume limits
  • Pressure, temperature and pass strategy
  • Voltage, installation environment and delivery market
  • Required documents, training, commissioning and spares

Request a Solution

FAQ

Benchtop High Pressure Homogenizer FAQ

These questions reflect Google People also ask themes for this product category. Model-specific limits and commercial terms remain quotation-stage confirmations.

What is the purpose of a high-pressure homogenizer?

A high-pressure homogenizer supports controlled dispersion, emulsification or cell-disruption work by processing a defined feed through a high-pressure step. PT-20 is positioned for benchtop laboratory development; confirm the target result and feed.

What is the purpose of a homogenizer?

A homogenizer is used to make a process result more uniform and repeatable for a defined liquid, suspension or cell feed. The PT-20 setup should be selected against the actual formulation and validation method.

What is the cost of a high pressure homogenizer?

A universal PT-20 price is not published. Request a quote that identifies the configuration, pressure and flow rating, contact materials, documents and service scope.

What is the main difference between a homogenizer and a high shear mixer?

The equipment can use different process mechanisms and operating windows even when the application is described as dispersion or emulsification. Compare the target result, viscosity, particle or cell load and validation plan for PT-20.

How do I choose a benchtop high pressure homogenizer for a trial?

Start with the formulation, batch volume, viscosity, feed particles or cells, target result and available utilities. Ask CAS PETER to confirm the PT-20 pressure, flow, materials and pass strategy for the quoted setup.

What should a benchtop homogenizer quote include?

Include the material, application, result criteria, throughput or batch volume, viscosity, particle size, voltage, installation environment, required documents and service scope. Price, MOQ, lead time and warranty require confirmation.

Product Features

Performance

Process Capability

Model selection should be matched to material properties, target capacity, and the degree of process control required for your application.

Technical Highlights

  • Higher laboratory throughput
  • Repeatable trial conditions
  • Practical scale-up reference

Suitable Applications

  • Food and beverage trials
  • Cosmetic formulation
  • Fine chemical development

Application Cases

Material testing, research projects, and industry exhibition records

Discuss High Pressure Homogenizer Model PT-20Share your material, target capacity, and process objective. CAS PETER will help assess whether this model is suitable for your project.